Each platform unit shall be installed so that
Web(1) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … WebDec 27, 2002 · (3) Dwelling Unit(s). At a dwelling unit, one 15A or 20A, 125V receptacle shall be located not less than 10 ft and not more than 20 ft from the water. This receptacle shall be located not more than 6 ft 6 in. above the floor, platform, or grade level serving the pool, outdoor spa or hot tub.
Each platform unit shall be installed so that
Did you know?
Web3314.5.1 Platform Spacing. Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (25 mm) wide except where a qualified person can demonstrate that a wider space is ...
Web(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … Web1) "Each scaffold and scaffold component must support its weight and _____ the maximum intended load applied to it." _____ p) 60: 2) "Each platform unit shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than _____ wide."
Web(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … WebEach platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (i) Each platform unit (e.g., …
Web3314.5.1 Platform Spacing. Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between …
WebEach platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … Occupational Safety & Health Administration. 200 Constitution Ave … cinnamon bay interiors yarmWebrollers if the suspended platform is not more than 130 feet (or 39.6 meters) above a safe working surface; and An alternative stabilization system if a registered professional … diagon alley factsWebThe maximum rated output capacity of hydrogen-generating appliances shall not exceed 4 standard cubic feet per minute (0.00189 m 3 /s) of hydrogen for each 250 square feet (23.2 m 2) of floor area in such spaces. The minimum cross-sectional dimension of air openings shall be 3 inches (76 mm). diagon alley foodWebbuilding. As each level of brick or concrete block is put in place, the scaffold is cranked up to the next level. When the work is done at the top of the wall, then the scaffold is cranked back down to the ground and disassembled. Gilbane witnesses testified this scaffold had been on the job site for months. TE 114. cinnamon bay in st johnWebequivalent means, shall extend over the centerline of its support at least 6 inches. 1926.451(b) – Scaffold Platform Construction (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (i) Each platform unit shall be installed so that the space cinnamon bay interiorsWebBuilding Code 2024 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 410 Stages, Platforms and Technical Production Areas > 410.3 Platform … diagon alley gift shopWebEach platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the … cinnamon bay leaf and green tea