WebBuy Worcester Bosch Filling Loops Flues & Boiler Accessories at Screwfix.com. Thousands of products. Buy online & collect in hundreds of stores in as little as 1 minute! UK call centre ready for your call 24/7. The UK’s leading retailer of trade tools and hardware. WebJun 3, 2024 · Mike83 Screwfix Select. If the filling loop is disconnected or you know it’s definitely not passing then it’s probably the plate heat exchanger at fault. This can be confirmed by monitoring the pressure on the boiler. If the pressure keeps rising but then stops when you turn the main off under the boiler then it points to the plate heat ...
Location of motorised valve and filling loop questions Screwfix ...
WebSep 10, 2024 · KIAB, Sep 10, 2024. #3. PlatypusGB New Member. KIAB said: ↑. Tried tapping the gauge, might be stuck. Thanks KIAB but I know the system volume is down from draining the large radiator. Even if it was just the guage I'd expect some movement of water through the filler hose at this point. PlatypusGB, Sep 10, 2024. #4. WebApr 2, 2024 · Hi all, I have an Electromax boiler (Heatrae Sadia), and I'm having a pressure issue. The pressure is near to 0.5, I know that it should be about 1.5. The filling loop was already connected, so my understanding is that opening both the valves of the filling loop the pressure should start going up. But when I open the valves nothing change (no ... shooting in texas over the weekend
Ideal Logic Combi filling loop issue Screwfix Community Forum
WebSep 9, 2024 · Order online at Screwfix.com. Filling loop with non-return valve. FREE next day delivery available, free collection in 1 minute. www.screwfix.com Reply. Q. QSMC. Messages 3. Sep 9, 2024 #5 ShaunCorbs said: Whole new filling loop but you can use the flexi off that and install it onto the valves you have and then just keep the valves for spares WebJan 17, 2024 · However, in the last month the filling loop only seems to ad hoc of the time. When the filling loop is working you can hear the water running through the loop and the pressure going up. And the valve is easy to open. When the filling loop is not working, there is no flow sound of water. And the valve is hard to open. WebApr 10, 2024 · Appears to be leaking from the tap and also the hose connector. Check valve seems fine. New check valve comes with new filling loop but will leave old one in place to save draining the system for now. May also shorten water supply pipe as hose is bent rather sharpish - only just noticed after maybe 12 years, but boiler is in the loft so not ... shooting in texas today news